Manual 2100-467K
Page 1 of 24
SINGLE PACKAGE
AIR CONDITIONERS
MODELS
PA13242-A PA13302-A
PA13362-A PA13362-B
PA13422-A PA13422-B
PA13422-C PA13482-A
PA13482-B PA13482-C
PA13602-A PA13602-B
PA13602-C
INSTALLATION INSTRUCTIONS
Manual : 2100-467K
Supersedes: 2100-467J
File: Volume II Tab 10
Date: 07-25-12
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Since 1914 . . . Moving ahead just as planned.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Bryan, Ohio 43506

Manual 2100-467K Page 1 of 24SINGLE PACKAGEAIR CONDITIONERSMODELS PA13242-A PA13302-A PA13362-A PA13362-B PA13422-A PA13422-B PA13422-C PA13482-

Pagina 2 - CONTENTS

Manual 2100-467K Page 10 of 24INSTALLATIONLOCATIONGENERAL The unit must be located outside, or in a well ventilated area. It must not be in the spac

Pagina 3 - THESE PUBLISHERS:

Manual 2100-467K Page 11 of 2436" min.24" min.24" min.The distance between1 inch clearanceAccessAir InletComp-Nearest StructureAir Inl

Pagina 4 - GENERAL INSTRUCTIONS

Manual 2100-467K Page 12 of 24FIGURE 4ELEVATED MOUNTING PLATFORMBoth legs must reston surface of platform32°F or lower climate12" min. if in48

Pagina 5 - ELECTRICAL SPECIFICATIONS

Manual 2100-467K Page 13 of 24FIGURE 5CONDENSATE DRAIN TRAP5. OTHER INSTALLATIONS – Many other installations are possible with the packaged air co

Pagina 6 - TABLE 3

Manual 2100-467K Page 14 of 24TABLE 6THERMOSTAT WIRE SIZETRANSFORMER TAPS230/208V, 1 phase and 3 phase equipment employ dual primary voltage transfo

Pagina 7 - TABLE 4

Manual 2100-467K Page 15 of 24EY1120-445TH5220D1151Low Voltage WiringL2CO1Unit Control PanelBlockYCG RW1 W2EFY1CG RW1OY2 W2DAELAUXRGEBRC3LBThermostat

Pagina 8 - Unit Dimension Chart

Manual 2100-467K Page 16 of 24START UPThese units require R-410A refrigerant and Polyol Ester oil.GENERAL:1. Use separate service equipment to avoid

Pagina 9 - DIMENSIONS OF UNITS

Manual 2100-467K Page 17 of 24THREE PHASE SCROLL COMPRESSOR START UP INFORMATION(Models PA13362-B; PA13422-B, -C; PA13482-B, -C; PA13602-B, -C)All un

Pagina 10 - INSTALLATION

Manual 2100-467K Page 18 of 24LOW PRESSURE SWITCH, BYPASS, AND LOCKOUT SEQUENCE (Standard Feature)If the low pressure switch opens for more that 120

Pagina 11 - Return Duct

Manual 2100-467K Page 19 of 24FAN BLADE SETTINGSShown in Figure 8 are the correct fan blade setting dimensions for proper air delivery across the out

Pagina 12 - * AS REQUIRED

Manual 2100-467K Page 2 of 24CONTENTSGetting Other Informations and Publications ...3General InstructionsImportant ...

Pagina 13 - AIR FILTERS

Manual 2100-467K Page 20 of 24(Continued on Page 20 in Table 11)TABLE 9PRESSURE TABLECOOLINGAir Temperature Entering Outdoor Coil Degree FLOW SIDE P

Pagina 14 - THERMOSTATS

Manual 2100-467K Page 21 of 24TABLE 10PRESSURE TABLELOW SIDE PRESSURE +4 PSIGHIGH SIDE PRESSURE +10 PSIGTablesbaseduponratedCFM(airow)across

Pagina 15 - Low Voltage Wiring

Manual 2100-467K Page 22 of 24SUCTION AND DISCHARGE TUBE BRAZINGCompliant Scroll compressors have copper plated steel suction and discharge tubes. T

Pagina 16 - START UP

Manual 2100-467K Page 23 of 24FIGURE 10NOTE: Bard Models PA13242; PA13302; PA13362-A, -B; PA13422-A, -B, -C; PA13482-A, -B, -C; PA13602-A, -B, -C c

Pagina 17 - START UP AND OPERATION

Manual 2100-467K Page 24 of 24FIGURE 11TROUBLESHOOTING GE X13-SERIES ECM2.3™ MOTORS CONT’D.Model X13 Communication Diagnostics The X13 motor is c

Pagina 18 - LOW AMBIENT CONTROL

Manual 2100-467K Page 3 of 24Getting Other Information and PublicationsThese publications can help you install the air conditioner or heat pump. You

Pagina 19 - MD-1417BC

Manual 2100-467K Page 4 of 24GENERAL INSTRUCTIONSIMPORTANTThe equipment covered in this manual is to be installed by trained, experienced service and

Pagina 20 - PRESSURE TABLE

Manual 2100-467K Page 5 of 24TABLE 2ELECTRICAL SPECIFICATIONSModel PA13242-A PA13302-A PA13362-A PA13362-B PA13422-A PA13422-B PA13422-C PA13482-A P

Pagina 21 - TABLE 10

Manual 2100-467K Page 6 of 24TABLE 3OPTIONAL FIELD INSTALLED HEATER PACKAGES ONLY TO BE USED WITH THE MODELS INDICATEDHeater PackageModelVolts &

Pagina 22 - • To connect:

Manual 2100-467K Page 7 of 24TABLE 4OPTIONAL FIELD INSTALLED ELECTRIC HEATER TABLEIMPORTANT: While this electrical data is presented as a guide, it

Pagina 23 - POWERED BY LINE VOLTAGE

Manual 2100-467K Page 8 of 24FIGURE 1ADIMENSIONS OF UNITSReturn openingDrain accessSupply openingHigh voltage knockoutLow voltage knockoutaccess doo

Pagina 24

Manual 2100-467K Page 9 of 24FIGURE 1BDIMENSIONS OF UNITSA BCDFEDAHGUNIT A B C D E F GHPA/PH1324, 1330,1336 7 3/16" 38 13/16" 36 3/4"