Bard WA3S Manual de usuario

Busca en linea o descarga Manual de usuario para Acondicionadores de aire del sistema de división Bard WA3S. S3378 (2014 09) - Bard Manufacturing Company Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Form No. S3378-914
Supersedes S3378-1013
Page 1 of 12
Multi-Capacity Two-Stage:
Simple thermostatic control
seamlessly stages the compressor
and indoor airow rate between
high and low capacity operations
without cycling the compressor. This
helps to maximize comfort, humidity
control, energy efciency and overall
reduction in compressor cycling for
improved system life.
Multi-Step Capacity Compressor:
Copeland step-capacity scroll
compressors are designed for
increased efciency, quieter operation
and improved reliability for longer life.
R-410A Refrigerant:
Designed with R-410A (HFC)
non-ozone depleting refrigerant in
compliance with the Montreal protocol
and 2010 EPA requirements.
ECM Indoor Blower Motor:
Features a variable speed motor
providing super-high efciency,
low sound levels and soft-start
capabilities.
The motor is self-
adjusting to provide the proper airow
rate for the staged capacity, and
for higher static pressure in ducted
installations without user adjustment or
wiring changes.
Aluminum Finned Copper Coils:
Grooved tubing and enhanced
louvered n for maximum heat
transfer and energy efciency.
The Bard WA/L “S” Series is the world’s most energy efcient wall mounted air
conditioner featuring a multi-step capacity compressor with environmentally
friendly non-ozone depleting refrigerant.
The Bard Wall-Mount Air Conditioner is a self contained energy efcient
system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor oor space or outside ground space. This
unit is the ideal product for versatile applications such as: new construction,
modular ofces, school modernization, telecommunication structures, portable
structures or correctional facilities. Factory or eld installed accessories are
available to meet specic job requirements.
Twin Blowers:
Move air quietly. All models feature
variable speed blower motors
providing automatic airow adjustment
for high static or free blow (non-ducted)
operation at a very low sound level.
Motor overload protection is standard
on all models.
Foil Faced Insulation:
Standard on all units.
Start Kit:
A PTCR compressor start assist
(Positive Temperature Coefcient
Resistor) is standard on all -A
single-phase models to increase
system reliability. This helps to
insure compressor starts at adverse
conditions by increasing the
compressor starting torque.
Compressor Control Module:
Built-in off-delay timer adjustable
from 30 seconds to 5 minutes.
2-minute on-delay if power interrupt.
120-second bypass for low pressure
control, and both soft and manual
lockouts for high and low pressure
controls. Alarm output for alarm relay.
Liquid Line Filter Drier:
Standard on all units. Protects
system against moisture.
High & Low Pressure Switches
are Auto-Reset:
Standard on all units. Built-in lock-
out circuit resets from the room
thermostat. Provides commercial
quality protection to the compressor.
Engineered Features
THE WALL-MOUNT™ STEP CAPACITY AIR CONDITIONERS
Integrated Part Load Value (IPLV) Efciency Up To 15.3 BTU/WATT
Crankcase Heaters:
Factory installed crankcase heaters
are standard on all models. This
helps to insure ease of start at
low temperatures and improves
compressor life.
Phase Rotation Monitor:
Standard on all 3 phase scroll
compressors. Protects against
reverse rotation if power supply is not
properly connected.
Galvanized 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
nished with a baked on textured
enamel, which allows it to withstand
1000 hours of salt spray tests per
ASTM B117-03.
Galvanized 16 Gauge Zinc
Coated Unit Base:
The unit base is treated with the same
paint coatings as the cabinet above,
insuring years of service without
visible corrosion.
Drain Pan:
The evaporator drain pan is
constructed of stainless steel material
for maximum corrosion resistance.
Electrical Components:
Are easily accessible for routine
inspection and maintenance through
a right side, service panel opening.
Features a lockable, hinged access
cover to the circuit breaker or toggle
disconnect switch.
Electric Heat Strips:
Features line break automatic limit
and dual backup safety controls.
Heater packages can be factory or
eld installed for all models.
Filter Service Door:
Separate service door provides easy
access for lter change.
Two-Inch, Pleated Disposable Air
Filters:
Are standard equipment.
Condenser Fan and Motor
Shroud Assembly:
Slides out for easy access.
Circuit Breakers/Rotary
Disconnect:
Standard on all versions of single
(230/208 volt) and three phase (230/208
volt) equipment. Rotary disconnects
are standard on all versions of three
phase (460 volt) equipment.
Slope Top:
Standard feature for water run-off.
Full Length Mounting Brackets:
Built into cabinet for improved
appearance and easy installation.
NOTE: Bottom mounting bracket
included to assist in installation.
Top Rain Flashing:
Standard feature on all models.
Green refriGerant
r-410a
WA3S – WA5S Right Side Control Panel
WL3S – WL5S Left Side Control Panel
3 to 5 Ton (35,400 to 56,500 Btuh) 60Hz
Complies with efciency requirements of ANSI/ASHRAE/IESNA 90.1-2010.
Certied to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units).
Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL
1995/CSA 22.2 No. 236-05, Fourth Edition.
Commercial Product - Not intended for Residential application.
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Green refriGerant

Form No. S3378-914Supersedes S3378-1013Page 1 of 12Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor

Pagina 2 - Page 2 of 12

Form No. S3378-914Supersedes S3378-1013Page 10 of 12ModelD.B./W.B.kCooling CapacityBTU/HR50°F 55°F 60°F 65°F 70°F 75°F 80°F 85°F 90°F 95°F 100°F 105

Pagina 3 - Ventilation System Packages

Form No. S3378-914Supersedes S3378-1013Page 11 of 12All dimensions are in inches. Dimensional drawings are not to scale.11"3"CondenserFil

Pagina 4 - WA5S/WL5S Ventilation Airflow

Models All ModelsDescriptionFactory InstalledCode No.Field InstalledPart No. Blank-Off Plate B BOP-5 Motorized Fresh Air Damper M MFAD-5 Commercial Ve

Pagina 5 - Page 5 of 12

Form No. S3378-914Supersedes S3378-1013Page 2 of 12ModelsWA3S3WL3S2WA4S3WL4S2WA5S3WL5S2Cooling Capacity BTUH, 2nd Stage Operation EER 2nd Stage Ope

Pagina 6 - Electrical Specications

Form No. S3378-914Supersedes S3378-1013Page 3 of 12Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventil

Pagina 7 - Electric Heat Table

Form No. S3378-914Supersedes S3378-1013Page 4 of 120100200300400500600700800900100002.557.51012.51517.52022.52527.530Ventilation Airflow (CFM)Vent P

Pagina 8 - Patent Pending

Form No. S3378-914Supersedes S3378-1013Page 5 of 12LEGEND:VLT = Ventilation Load - TotalVLS = Ventilation Load - SensibleVLL = Ventilation Loa

Pagina 9 - Page 9 of 12

Form No. S3378-914Supersedes S3378-1013Page 6 of 12 Electrical Specicationsj Maximum size of the time delay fuse or HACR type circuit breaker for

Pagina 10 - Page 10 of 12

Form No. S3378-914Supersedes S3378-1013Page 7 of 12NominalKWAt 240V (1) At 208V (1) At 480V (2) At 460V (2)Kw1-Ph Amps3-Ph AmpsBtuh Kw1-Ph Amps3-Ph

Pagina 11 - WL3-4-5S Models

Form No. S3378-914Supersedes S3378-1013Page 8 of 12Optional Installation AccessoriesDescription Model ColorShippingWeight (Lbs.)Return AirAcoustical

Pagina 12 - Ventilation Options

Form No. S3378-914Supersedes S3378-1013Page 9 of 12Typical Sound Performance with Installation/Isolation Curbs & Acoustical PlenumsWA/L3S Sound

Comentarios a estos manuales

Sin comentarios